An electrician interview scorecard should score six lines separately: safe work practices, code knowledge and application, troubleshooting, installation quality, drawings and job planning, and communication with customers and other trades. Weight safety and troubleshooting highest, and write each line's 1, 3 and 5 in the trade's own terms: whether the candidate tests the meter on a known live source before trusting a dead reading, whether they know which code edition their jurisdiction enforces, whether they isolate a fault or swap parts until it stops. The state or city license the job requires is a pass or fail check, not a score.
The scale is the 1–5 interview rating scale and the layout is the interview scorecard template. The recruiter's knockouts (license level, setting, travel) are covered in electrician screening questions; this scorecard is for the technical interview and the practical that follow, run by a foreman, superintendent or master electrician who can judge the answers.
Which competencies should an electrician scorecard cover?
- Safe work practices. De-energizes, locks and tags out, verifies absence of voltage, and refuses to work live for convenience.
- Code knowledge and application. Knows which edition of the National Electrical Code is enforced where they work and how to look up a requirement.
- Troubleshooting and diagnostics. Uses meters and a method to isolate a fault, and finds the cause before replacing parts.
- Installation quality. Terminations, conduit, wire management and labeling that pass inspection the first time.
- Drawings and job planning. Reads prints and panel schedules, plans materials and sequence, and spots conflicts before they cost a day.
- Communication and teamwork. Explains the work to customers, coordinates with other trades and supervisors, and guides apprentices.
Score only what the job description lists as essential. Under the federal ADA regulations, a written job description prepared before advertising or interviewing is evidence of which functions are essential (29 CFR 1630.2(n)(3)(ii)), and reasonable accommodation includes changes to the application process itself (1630.2(o)(1)(i)). See ADA accommodations in interviews.
The scorecard: weights and what a 1, 3 and 5 look like
Example weights for a journeyman on commercial work. Adjust for the seat and lock them before the first candidate.
| Competency | Weight | 1 looks like | 3 looks like | 5 looks like |
|---|---|---|---|---|
| Safe work practices | 25% | "I just turn off the breaker"; no lock, no test, or works circuits hot to save time | Locks and tags out, tests the meter on a known live source, verifies absence of voltage, retests the meter | Also checks for shared neutrals and backfeed, stops a job that was set up unsafely, and explains why to the customer and the supervisor |
| Code knowledge and application | 20% | Cannot say which code edition applies; "the inspector will tell me" | Names the edition enforced locally, finds a requirement in the codebook and applies it to the task | Explains how a local amendment or an inspector's interpretation changed a job, and plans for it before rough-in |
| Troubleshooting and diagnostics | 20% | Replaces devices until the problem stops | Gathers the symptoms, isolates the circuit and loads, uses the right meter test and confirms the cause | Finds an intermittent or multi-cause fault, explains the evidence for each step, and documents it for the next tech |
| Installation quality | 15% | Describes failed inspections as the inspector's fault | Neat, labeled, properly terminated work; can describe torque, support and box fill habits | Others copy their layouts; describes catching a quality problem in a crew's work before inspection |
| Drawings and job planning | 10% | Cannot read a panel schedule or one-line drawing | Reads prints, builds a material list and sequence, flags conflicts with other trades | Ran a section of a job: planned manpower and materials and caught a design conflict before installation |
| Communication and teamwork | 10% | Blames other trades or the customer; cannot explain the work simply | Explains an outage or a change to a customer, coordinates with other trades, answers an apprentice's question patiently | Trains apprentices on purpose and resolves a trade conflict without the superintendent stepping in |
A 2 shows part of the 3 behavior, or needs prompting; a 4 shows the 3 behavior and part of the 5. Mark a line "not assessed" if it never came up. Communication is scored on clarity, never accent or speaking style.
Copy-ready electrician scorecard
Candidate: [name] Seat: [residential / commercial / industrial / service] License level: [ ]
Interviewer: [name] Stage: [technical interview / practical / foreman / final]
Competency Weight Score (1-5 or N/A) Evidence (what they said or did)
Safe work practices 25% [ ] [lockout steps, meter check, live-work answer]
Code knowledge and application 20% [ ] [edition named, requirement found and applied]
Troubleshooting and diagnostics 20% [ ] [symptoms gathered, isolation steps, cause]
Installation quality 15% [ ] [practical result or described habits]
Drawings and job planning 10% [ ] [print reading, material list, conflicts]
Communication and teamwork 10% [ ] [customer, trades, apprentices]
Requirements (pass/fail, not scored): [license at required level, verified on state/city lookup]
[OSHA or other training cards if the job requires them, verified] [driver's license if the job drives]
Weighted score: [ ] Open questions: [ ] Recommendation: [Strong yes / Yes / No / Strong no]
What should each interviewer ask, and what counts as evidence?
Safe work practices
Use the live-work scenario below. The federal rule behind the 3 anchor: OSHA's general industry standard says a qualified person must use test equipment to verify that circuit parts are de-energized, and that the test must also check for induced voltage or backfeed (29 CFR 1910.333(b)(2)(iv)(B), as of November 2026). Score the habit they describe, not whether they quote the rule.
Code knowledge and application
Ask: "Which edition of the NEC is enforced where you work now, and how do you look something up on the job?" NFPA 70, the National Electrical Code, is published by NFPA; its current edition is 2026, and states and cities adopt editions on their own schedules, which NFPA tracks on its NEC enforcement maps (as of November 2026). A candidate working to an older adopted edition is not wrong; one who does not know is a 1 or 2.
Troubleshooting and diagnostics
Use the tripping-circuit scenario below. Evidence: questions before tools, one variable at a time, the cause confirmed before a part is replaced.
Installation quality
Best scored in a short practical: terminate a device and a panel connection, or bend an offset and a 90 in conduit to a marked layout, with every candidate given the same task, tools and time. If you ask everyone in the job category to demonstrate a task, the EEOC's guidance allows it, and a candidate who needs an accommodation must get one or be allowed to describe the task instead (EEOC guidance on pre-employment questions).
Drawings and job planning
Hand over one sheet of a real (or sanitized) print and a panel schedule. Ask for a material list for one room and the order they would work in. Evidence: reads the symbols and notes, and asks about the things the print does not show.
Communication and teamwork
Ask: "Tell me about a time another trade's work got in the way of yours." and "How do you teach an apprentice to terminate a panel?" Evidence: a fix agreed on site, and teaching that includes the why, not just the how.
Two scenarios that produce scoreable evidence
Pressure to work it live (10 minutes). "You are adding a circuit in a retail store's panel. The store manager says the panel cannot go dark during business hours and asks you to make the tie-in live. Your foreman is on another site. What do you do?"
What to listen for: a clear no to energized work for convenience. OSHA's rule is that live parts are de-energized before work unless the employer can show that de-energizing creates additional or increased hazards or is infeasible because of equipment design or operational limitations (29 CFR 1910.333(a)(1)), and a store's opening hours are neither. On construction work, the construction rule requires protection by de-energizing and grounding the circuit or by guarding it effectively (29 CFR 1926.416(a)(1)). Strong answers offer an after-hours shutdown or a short planned outage, call the foreman, and explain the reason to the manager politely. A 5 also mentions the company's energized work procedure and that the decision is not the journeyman's alone.
An intermittent trip (15 minutes). "A 20-amp kitchen circuit in a house trips now and then, usually when the dishwasher runs (invented). The homeowner has already replaced the GFCI receptacle once. Walk me through finding the cause."
What to listen for: asking what trips (the GFCI device or the breaker, and what kind of breaker), what else is on the circuit and whether it happens in wet weather; separating an overload from a ground fault; disconnecting loads and testing the circuit wiring and the appliance separately with the right instrument; checking for a shared neutral or moisture in a box; and explaining the finding to the homeowner before replacing anything.
A filled example
A made-up candidate for a commercial journeyman seat:
Safe work practices: 4 (25%). Refused the live tie-in, proposed a 6 a.m. shutdown and said they would call the foreman before answering the manager. Described live-dead-live testing unprompted; did not mention backfeed.
Code knowledge and application: 3 (20%). Named the edition their city enforces and found a box fill rule in the codebook in about two minutes.
Troubleshooting and diagnostics: 3 (20%). Separated breaker from GFCI trips and isolated the dishwasher; went to replacing the dishwasher cord before testing the appliance.
Installation quality: 4 (15%). Practical termination was neat, labeled and torqued to the marking on the device.
Drawings and job planning: 2 (10%). Read the print but missed a note that changed the conduit size, and did not ask about it.
Communication and teamwork: 3 (10%). Good example of rerouting around a plumber's line after a short conversation on site.
Weighted score: 3.3 of 5. (0.25 x 4 + 0.2 x 3 + 0.2 x 3 + 0.15 x 4 + 0.1 x 2 + 0.1 x 3.) Recommendation: Yes, pending the license check on the state lookup.
How do you adjust it for the seat and the level?
| Seat or level | What changes |
|---|---|
| Residential and service | Weight customer communication higher (15–20%); troubleshooting scenarios in occupied homes. |
| Commercial construction | The weights above; drawings and coordination with other trades matter more on larger jobs. |
| Industrial and maintenance | Add a line for motor controls, PLC inputs and outputs or instrumentation if the job lists them; troubleshooting up to 25–30%. |
| Apprentice | Score safety attitude, willingness to learn and basic tool and math skills; drop code and planning; the apprenticeship program sets the training. |
| Foreman or master | Add a line for running a crew (manpower, schedule, safety meetings); a 3 in planning requires a job they ran. |
Mistakes specific to scoring electricians
| Mistake | Why it fails | Fix |
|---|---|---|
| Scoring years in the trade | Ten years of unsafe habits score higher than three years of good ones | Score the behavior in the scenarios and the practical |
| Treating the license as a skill score | Double counts a legal requirement and hides real gaps | Verify the license pass or fail; score the work |
| No practical, only talk | Installation quality cannot be judged from a description alone | Run the same short practical for every candidate, with accommodations on request |
| Scoring code recall by article number | Memory of numbers is not the same as finding and applying a rule | Let them use the codebook; score the lookup and the application |
| Asking about injuries or medical history | Disability-related questions are not allowed before a conditional offer | Ask only whether they can perform the listed essential functions, with or without accommodation |
Where does this scorecard fit in the hiring process?
Write the rows from the must-haves in the electrician job description template, screen with the recruiter's knockouts, verify the license on the state or city lookup (see how to verify an electrician license), then run the technical interview and the practical with the scorecard. Medical examinations, if the job uses them, wait until after a conditional offer (see pre-employment medical exams under the ADA). The broader trade loop is in the interview guide for skilled trades.
If you hold the technical interview on a video call with Interview Signal, our desktop app, you can enter these competencies as the role's scorecard areas: it scores each area from 1 to 10 during the call with the candidate's own quotes as evidence, deletes any quote not found word for word in the transcript, and caps an area with no surviving quote at 5, marked "Probe further" (see how the verified-quote scorecard works). The practical is still scored by the person watching it.
Questions people ask
What should an electrician interview scorecard measure?
Score safe work practices, code knowledge and how the candidate looks up a requirement, troubleshooting method, installation quality, reading drawings and planning the job, and communication with customers, supervisors and other trades. Weight safety and troubleshooting highest for most seats, and treat the state license as a pass or fail check rather than a score.
Should the electrician license level be scored in the interview?
No. The license the job requires, such as journeyman or master, is a pass or fail requirement verified on the state or city licensing lookup for the place the work is done. The scorecard scores what the candidate shows they can do safely and well within that license.
How do you test an electrician's safety habits in an interview?
Ask them to walk through a real task from arrival to re-energizing, and give them a scenario where a customer pressures them to work a circuit live. Listen for lockout and tagout, testing the meter on a known live source before and after checking for absence of voltage, and a refusal to work energized parts for convenience, with an escalation to a supervisor.
Can I ask an electrician candidate whether they can climb ladders or lift heavy materials?
You can ask every applicant whether they can perform the essential functions listed in the job description, with or without reasonable accommodation, and you can ask everyone in the job category to describe or demonstrate a task. Do not ask about medical conditions before a conditional offer, and score only essential functions.